Thermal
Calibration of thermal measuring instruments is a critical process in ensuring accurate and reliable temperature measurements in industrial applications. In industries such as pharmaceuticals, Manufacturing, Healthcare, petrochemicals, and food processing, precise temperature control is essential for quality control, process optimization, and compliance with regulatory requirements. Accurate temperature measurement is also important for ensuring worker safety and reducing the risk of equipment failure. Proper calibration of thermal measuring instruments helps to ensure that the temperature data obtained from these instruments is accurate and reliable, which is crucial for maintaining the quality of the final product, optimizing production processes, and complying with regulatory requirements. Regular calibration of thermal measuring instruments is a necessary part of any quality control program.
Instruments Which Can Be Calibrated:
Sl | Parameter*/Device under Calibration | Group | Range(s) of Measurement | CMC | Calibration Performed At |
---|---|---|---|---|---|
Recommended by Assessor | |||||
1 | Thermo Hygrometer, RHsensor/Transmitter with Indicator | Specific heat & Humidity | 15 % RH to 90 % RH @25°C | 1.39 %RH to 1.78 %RH | SiteFacility |
2 | Thermo Hygrometer, RHsensor/Transmitter with Indicator | Specific heat & Humidity | 15 %RH to 90 %RH @25°C | 1.78 | PermanentFacility |
3 | Data Logger with sensor(inbuilt/external) (Temperature) | Temperature | -30 °C to 50 °C | 0.17 °C to 0.24 °C | PermanentFacility |
4 | Glass Thermometer | Temperature | -30 °C to 200 °C | 0.85 | PermanentFacility |
5 | Indicator with sensor of deep Freezer,Environment Chamber,Liquid Bath, Dry Bath,Furnace (Single Position) | Temperature | 100 °C to 400 °C | 0.57 | PermanentFacility, SiteFacility |
6 | Indicator with sensor of deep Freezer,Environment Chamber,Liquid Bath, Dry Bath,Furnace (Single Position) | Temperature | -80 °C to 100 °C | 0.21 °C to 0.54 °C | PermanentFacility, SiteFacility |
7 | Indicator with sensor of deep Freezer,Environment Chamber,Liquid Bath, Dry Bath,Furnace (Single Position) | Temperature | 400 °C to 600 °C | 0.57 | PermanentFacility, SiteFacility |
8 | Indicator with sensor of Liquid Bath, Dry Bath, Furnace (Single Position) | Temperature | 600 °C to 1200 °C | 2.46 °C to 2.54 °C | PermanentFacility, SiteFacility |
9 | Indicator with sensor of Liquid Bath, Dry Bath, Furnace (Single Position) | Temperature | 100 °C to 400 °C | 0.54 °C to 0.54 °C | SiteFacility |
10 | IRThermometer,Pyrometer, Laser Gun | Temperature | 50 °C to 400 °C | 2.19 °C to 2.19 °C | PermanentFacility |
11 | IRThermometer,Pyrometer, Laser Gun | Temperature | 400 °C to 500 °C | 1.74 °C to 3.97 °C | PermanentFacility |
12 | Oven, Furnace, Deep Freezer, Environmental Chamber,BOD Incubator(industrial purpose only)(Multi Position minimum 9 sensor) | Temperature | -35 °C to 180 °C | 3.1 | SiteFacility |
13 | RTD/Thermocouple With/Without Controller/Indicator, Analogue Temp.Gauge, Temp. Transmitter | Temperature | -80 °C to 600 °C | 0.30 °C to 0.42 °C | SiteFacility |
14 | RTD/Thermocouple With/Without Controller/Indicator/ Analogue Temp.Gauge, Temp. Transmitter | Temperature | 50 °C to 600 °C | 0.36 °C to 0.42 °C | PermanentFacility |
15 | RTD/Thermocouple With/Without Controller/Indicator/ Analogue Temp.Gauge, Temp. Transmitter | Temperature | -80 °C to 50 °C | 0.13 °C to 0.36 °C | PermanentFacility |
16 | Thermo Hygrometer, Temp/R HSensor/Transmitter with Indicator | Temperature | 10 °C to 50 °C @50% RH | 0.38 °C to 0.38 °C | PermanentFacility |
17 | Thermo Hygrometer,Temp/R HSensor/Transmitter with Indicator | Temperature | 10 °C to 50 °C @50% RH | 0.33 | SiteFacility |
18 | Thermocouple With/Without Controller/Indicator | Temperature | 600 °C to 1200 °C | 2.49 | SiteFacility |
19 | Thermocouple With/Without Controller/Indicator | Temperature | 600 °C to 1200 °C | 1.85 °C to 2.49 °C | PermanentFacility |